About the Daniel Wedge Meter
While the wedge meter can handle clean liquid, gas and steam, the meter particularly excels at difficult to-measure abrasive, corrosive, solid-laden and viscous fluids or fluids that tend to easily foul, that other DP primary elements cannot accurately measure or withstand the wear an tear. Common applications for wedge meters include asphalt, cement, tar-sands, sewage systems, fracking fluids, wastewater and many, other industrial and petrochemical applications where abrasive and/or corrosive fluids need to be measured
Performance and Physical Specifications
Standard Accuracy | Calibrated: ± 0.5%; Uncalibrated: ±5.0% of actual flow |
Flow Ranges (turndown) | 10:1 or greater |
Repeatability | ± 0.2% or better |
Permanent Pressure Loss | Varies with DP and Beta (H/D) Ratio |
Beta Ration | 0.2, 0.3, 0.4, 0.5; Additional betas available by request |
Line Sizes and Pressure Ratings | 2” to 24” – ANSI 150# thru 2500# 26”and larger – available in any flange specification |
Construction Materials | All Grades of Stainless Steel, Carbon Steel and Alloys or any other weldable material |
End Configuration | Wafer, Flanged, Beveled, Threaded and Others |
Approvals | CE-PED 2014/68/EU, CRN |
Features
- High accuracy of ±0.5%, Repeatability of ±0.2%
- Wide range of pipe sizes available from 2” to 24”
- End configuration available in flanged, threaded, beveled, hubs and welded
- All grades of SS, Duplex SS, Carbon Steel and other construction materials available by request